YBX4 Explosion-Proof Motor for Chemical and Petrochemical Plants
YBX4 explosion-proof motors may be used in chemical and petrochemical industries if your hazardous area, gas group and temperature class meet the nameplate markings. It is a completely enclosed flameproof three phase squirrel cage motor, with power range of 0.55 to 315 kW. Flames cannot reach the combustible gas outside. Explosion within the Ex-d cage. I prepared this guide to assist procurement managers and safety engineers feel confidence when they examine certifications, look at other possibilities and ask for quotations. It covers prerequisites, options, usage, setup, maintenance and purchase procedure.

Series:YBX4
Voltage range:380V,660V,415V,380/660V,660/1140V
Power range:0.55-315 kW
Application:places where explosive gas mixtures exist in petroleum, chemical, mining, metallurgy, electric power, machinery and other industries.
Advantage: fully enclosed, self-fan cooling, squirrel cage type, high efficiency.
Explosion-proof mark: Ex d I Mb, Ex d IIB T4 Gb, Ex d IIC T4 Gb
Others: SKF, NSK, FAG bearings can be replaced according to customer requirements.
What Is a YBX4 Explosion-Proof Motor?
How the Flameproof Enclosure Works?
However, even if the enclosure is flameproof ("Ex d") petrol may still enter the motor. But the housing is sturdy enough to withstand an internal explosion and the machined joints keep escaping gases below the ignition threshold of the outside air. The regulations for this form of protection are specified by IEC 60079-1 . How the YBX4 explosion-proof motor works: It is totally enclosed, squirrel cage rotor, self-fan ventilated cooling (IC411). The fan is outside the sealed container and the frame features ribs to transport heat away. Don’t ever paint over, grind or otherwise destroy the joints. They keep everything secure. A motor with fractured joint is not in agreement with its certificate anymore.
YBX4 Series Data at a Glance
As soon as someone asks me for a YBX4 explosion-proof motor, I look at these numbers first. Use them as a first filter, and then check each line on the datasheet.
| Item | YBX4 data |
|---|---|
| Power range | 0.55–315 kW |
| Voltage options | 380 V, 415 V, 660 V, 380/660 V, 660/1140 V |
| Frequency | 50 Hz (60 Hz available) |
| Frame sizes | H80–H355 |
| Poles | 2, 4, 6, 8 |
| Protection class | IP55 |
| Insulation class | F |
| Cooling | IC411, self-fan |
| Duty | S1 continuous |
| Explosion-proof marks | Ex d I Mb, Ex d IIB T4 Gb, Ex d IIC T4 Gb |
If you want, you can get SKF, NSK, or FAG bearings instead of the standard ones.
Flameproof Versus Ordinary Motors in Classified Areas
A standard fan-cooled motor that is completely enclosed is resistant to dust and water splashes, but it is not explosion-proof unless it is changed. Vapors that seep in could catch fire if there is a spark inside it. In the US, a Class I, Division 1 motor is usually marked as "explosion-proof." In Division 2 areas, the rules are different. Instead, the IEC zone system is used by the YBX4 explosion-proof motor, and its Gb level fits Zone 1. Article 505 of the NEC recognizes zone classification, but what it accepts is up to the authority that has power. I think you should talk to that authority about certification at the beginning of the project, before you place an order.
YBX4 Explosion-Proof Motor Specifications for Industrial Procurement
Gas Groups, Temperature Class, and Protection Level
Three marks will inform you if a motor will work with your procedure. Ex d IIB T4 Gb has gazes such as ethylene. The tightest gas group is Ex d IIC T4 Gb which includes hydrogen and acetylene. Ex d I Mb is a mining mark hence it cannot be used in a chemical plant. T4 is limited to a surface temperature of 135°C, which is suitable for gases that ignite above this temperature. Carbon disulphide requires a lower class since it burns at ~90 C. Zone 1 gear is rated Gb. The gas group should be clearly indicated on the nameplate of each YBX4 explosion-proof motor. I will run that group by you again before I quote.
Voltage, Power, and Frame Options
The series ranges from 0.55 kW to 315 kW from frame H80 to H355 and can match speeds with 2, 4, 6 or 8 poles. Typical voltages include 380V, 415V, 660V, 380/660V, 660/1140V at 50Hz. You may also have 60 Hz voltages. For international markets, unique 400V and 440V 60 Hz combinations are available. Please let us know in your initial communication whether your plant is 460V or 575V so the engineers can make sure the winding will perform what it has to do. All of the YBX4 explosion-proof motors are rated for S1 continuous duty with Class F insulation, making them capable of driving continuously operating fans and pumps.
Bearings, Coatings, and Accessories
If you want, you can get SKF, NSK, or FAG bearings instead of the standard ones. This is helpful for maintenance teams that already have one brand of bearings on hand. Standard IP55 protection keeps dust and water splashes out, so it's best to use it inside. For chemicals, rain, or damp air, pick an outdoor W type coating, an anti-corrosion WF1 or WF2 coating, or a tropical TH or THW treatment. You can change the length of the shaft, the way it is mounted, the location of the terminal boxes, the high-temperature or sealed bearings, the rain shields, the space heaters, and the vibration sensors. When you ask the first question, make a list of all the options, since each change affects both the drawing and the datasheet.
How to Select a YBX4 Explosion-Proof Motor for Hazardous Areas?
Start with Area Classification
When making a choice, the plant's area classification comes first, not the motor catalog. IEC 60079-10-1 and NFPA 497 explain how to group places that have gasses and vapors that can catch fire. In Zone 1, an explosive atmosphere is likely to happen from time to time during normal operations. Not likely in Zone 2, and if it does happen, it won't last long. Write down the zone, the gas group, and the temperature at which the most sensitive substance will ignite. Then, pick a temperature class that gives you some room to maneuver. A model name doesn't prove that it's right by itself. When you order a motor, the marks on it must match your classification drawing exactly, line for line, and a ybx4 dust proof motor manufacturer should insist on this practice.
Match Torque, Speed, and Starting Method
Check the area and then make sure the motor is the right size for the load. It's easy for a centrifugal pump to start up. More starting torque is needed for a conveyor or mixer that is full. Large fans and compressors have a lot of inertia, which makes them take longer to start up and raises the temperature of the windings. Next, make sure you know the duty, speed (from 2, 4, 6, or 8 poles), and how to start the motor by comparing the load torque curve to the motor curve. You should ask the supplier if the certificate covers drive operation if you want to use a variable-frequency drive. This is because the drive changes how the motor heats up. Set these things straight before you ask for a price.
YBX4 Explosion-Proof Motor vs. Ordinary and YBX3 Motors
Instead of just a motor, a certified YBX4 explosion-proof motor has a flameproof case, a temperature class that is marked, and a certificate that you can check. When compared to YBX3, the mounting dimensions stay the same, so a swap can happen without having to change bases. The newer series has a better electromagnetic design, a smaller case that reduces vibration, and heat-dissipation ribs that lower temperature rise. Still, I think you should check your drawing against the shaft height, foot-hole spacing, and flange dimensions before you place your order. A replacement is only a direct replacement if the sizes are the same, and you should also make sure that the certification still works in your zone.
Applications, Installation, and Maintenance
Typical Uses in Chemical and Petrochemical Plants
Most of the time, YBX4 explosion-proof motors are used in pumps and compressors that work with volatile hydrocarbons. Exhaust fans, process blowers, mixers, agitators, conveyors, and packaged skids are some of the other ways they are used. There are a lot of different types of sites, such as tank farms, storage terminals, blending areas, loading areas, and wastewater treatment plants. The same series is also used in coal mining, paint spraying, mixing pharmaceuticals with flammable solvents, and mixing paints. There needs to be a separate check for each use. In a tank farm, a pump and a mixer may be in different zones and gas groups, which is why their nameplate marks might be different.
Installation and Wiring Steps
Before switching on I compare the datasheet with the nameplate, certificate, voltage, frequency, speed and temperature class. Install blank off plates, conduit seals and approved cable glands and grounding conductor. IEC 60079-14 refers to the selection and installation of electrical equipment in hazardous areas. On the mechanical side, check for soft feet on the foundation, align the connection or belt, ensure the fasteners are tight enough and keep the fan cover open so that air can circulate. - Record insulation resistance, phase sequence, current, vibration, bearing temperature, noise, start time and rotation direction when the machine is put into operation. These records assist you to know what needs to be repaired in the future.
Maintenance and Troubleshooting for YBX4 Explosion-Proof Motors
Select inspection intervals depending on operation hours, environmental conditions and cost of an interruption. The current, vibration, temperature of bearings and windings, cooling tubes, terminal connections, glands, grounding, and corrosion should be considered. Old records compared with current measurements of insulation resistance may provide indications of moisture or wear and tear. When replacing bearings, use the proper kind and quantity of lubricant and spacing between bearings. Then verify the alignment and vibration again. Some typical issues include failure to start, excessive current, overheating, vibration, noise, and nuisance tripping. To fix parts that touch flameproof joints or enclosure dimensions, only qualified people should do it, and they should follow the right steps, and a ybx4 explosion proof ac motor supplier should provide this maintenance guidance.
Buying Guide: Certificates, Supplier Checks, and Delivery
Verify Certificate Numbers Before You Order
It's bad enough to lose a certificate, but it's terrible when someone says they have one and can't show it. Provide the explosion proof certificate number, the type test report and a photo of the nameplate for the specific model. Then validate the number with the organization that issued it. Check that the certificate shows the gas group, temperature class and protection level are suitable for your zone. If they don’t mention it, ask them why are the IIB and IIC both on a technical page. These two classes encompass other gases. Also be sure the place you are going to will accept the certification. In the case of a U.S. project, speak to the accepting authority as soon as feasible. “At XCMOTOR, before I quote you on a YBX4 explosion proof motor, I make sure we agree on the gas group.
Audit the Supplier and the Process
Qualification evaluation often starts with a certificate check. So then you have a sample unit, then a small batch, then a master supply agreement. It might take anything from 3 to 9 months. Ask each supplier to have a third party do a factory audit or video audit so you can observe how they manufacture, wind and test their goods. XCMOTOR begins the manufacturing process by selecting the correct materials, then cutting them using CNC machines. There’s also automatic winding and rotor balance, flame path and pressure testing, load testing and certification tests. Each explosion-proof motor YBX4 is supplied with test results of its performance including temperature increase, no-load and locked-rotor current, insulation resistance, high-voltage resistance and vibration.
Pricing, Minimum Order, and Lead Time
The price will be different for speed, power, frame size, gas group, coating, accessories, bearing brand, number and destination of the bike. Minimum order quantity is one item and normally takes 20 to 30 working days for delivery. If you need to buy a YBX4 explosion-proof motor, you need to know the voltage, frequency, mounting, duty, zone, gas group, temperature class, ambient conditions, driven equipment, starting method, delivery goal and voltage. When comparing offers, consider more than simply the unit price. Check the whole value including papers, testing, warranty, spare parts and delivery conditions. When a consumer wants to purchase a motorbike, XCMOTOR helps them find the proper brand, series and model. They deal directly with manufacturers and handle transportation by sea, land and air.
Conclusion
Chemical and petrochemical plants can only use a YBX4 explosion-proof motor if its markings match the area. The flameproof Ex-d enclosure has an explosion inside it, and the series includes 0.55–315 kW, different voltage options, Class F insulation, IP55 protection, and several voltage options. What works depends on the gas group and temperature class. IIB and IIC cover different gasses, and T4 keeps the surface temperature to 135°C. Area classification comes first, then load, speed, starting method, and environment. Compared to regular motors, the YBX4 has certified protection, and its dimensions are the same as those of the YBX3. The flameproof joints are kept safe by proper installation and regular checks. Buyers lower their risk by checking the validity of certificate numbers, visiting the factory, and sending a full specification so that supplier bids can be compared fairly.
FAQ
1. What does YBX4 mean?
The YBX4 series is a group of high-efficiency, flameproof, three-phase asynchronous motors from the fourth generation. Each YBX4 explosion-proof motor has a squirrel cage design that keeps everything inside. It also has self-fan cooling, Class F insulation, and IP55 protection.
2. Which explosion-proof marks apply?
Ex d I Mb is for mining, and Ex d IIB T4 Gb and Ex d IIC T4 Gb are for areas with flammable gasses. Before you order, make sure that the model you want has the right mark on its nameplate and certificate. IIB and IIC cover different gasses.
3. Can I use it outdoors or in corrosive sites?
Standard IP55 construction works for dangerous areas inside. You can get outdoor W type coatings, anti-corrosion WF1 or WF2 coatings, or tropical TH or THW treatments for salt air, wet air, or rain.
4. What are the minimum order and lead time?
You need to order at least one unit, and the lead time is usually twenty to thirty working days. Check the date against the options and quantity you have chosen.
5. Can I choose the bearing brand?
Yes. If you want, you can get SKF, NSK, or FAG bearings instead of the standard ones. When you send us your first question, let us know which brand you want so that the datasheet shows that.
Request a YBX4 Explosion-Proof Motor Quote from XCMOTOR
To XCMOTOR at xcmotors@163.com, send your zone, gas group, temperature class, power, voltage, and amount. As a provider of YBX4 explosion-proof motors, we offer free shipping, 30-day returns, original parts from well-known brands, and support on the weekends. Before giving you a quote, our team looks over your application to make sure that the YBX4 explosion-proof motor you get will work in your plant.
References
1. IEC 60079-1: Explosive Atmospheres – Part 1: Equipment Protection by Flameproof Enclosures "d" (2014)
2. IEC 60079-0: Explosive Atmospheres – Part 0: Equipment – General Requirements (2017)
3. IEC 60079-10-1: Explosive Atmospheres – Part 10-1: Classification of Areas – Explosive Gas Atmospheres (2020)
4. IEC 60079-14: Explosive Atmospheres – Part 14: Electrical Installations Design, Selection and Erection (2013)
5. NFPA 70: National Electrical Code (2023)
6. NFPA 497: Recommended Practice for the Classification of Flammable Liquids, Gases, or Vapors and of Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas (2021)
YOU MAY LIKE
VIEW MOREslip ring motor
VIEW MOREYXKK series high voltage and high efficiency motor
VIEW MOREYPKK series high voltage frequency asynchronous motor
VIEW MORElong shaft ac motor
VIEW MORE3 phase cage induction motor
VIEW MOREwater cooled electric motor
VIEW MOREYBSD explosion-proof conveyors motors
VIEW MORE100 hp soft starter